Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 114

Advertising
background image

TROUBLESHOOTING

1-111

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE E1154

Option SIO port is not installed.

Main causes include:
1. Optional communication port (1GS board) is not installed to the 1KA board.
2. Optional communication port (1GS board) is not recognized by the 1KA board.

⇒

Install the optional communication port (1GS board) onto the 1KA board.

⇒

Replace the 1KA board.

_____________________________________________________________________

ERROR CODE E1155

A/D converter is not installed.

A/D converter board (1FH) is not installed to the 1KA board.

⇒

Install the A/D converter board (1FH).

_____________________________________________________________________

ERROR CODE E1156

[ARM CONTROL BOARD] Processing time over.

AS software processing did not complete within normal time.

⇒

Reset the error.

⇒

If this error recurs, contact KRI customer service

.

_____________________________________________________________________

Advertising