TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-16

August 9, 2005

Ka a a

w s k

ERROR CODE D0005

[ARM CONTROL BOARD] CPU BUS error. (PC=XX)

On the 1KB board, a bus error occurs (in the VME bus line, detected by AS software);
data processing is not completed normally. This error is caused by defective AS soft-
ware, defective 1KB board, or noise related malfunction.

PC Error Display Example:

Error (D0005) [ARM CONTROL BOARD] CPU BUS error Code=1

Task (Pc01) Stop SIG=00070004 [NMI(

)] PC=*****

VME BUS ERROR

Indicates the place the error occurred

⇒

Refer to the error message displayed on a PC interfaced with the controller.

⇒

Cycle controller power OFF and ON. Do not initialize the controller

.

If a message for

initialization is displayed, select “NO”.

⇒

Ensure the correct 1KB board software is loaded into the 1KA board.

⇒

Replace the 1KB board.

⇒

If the above steps do not correct the error, contact KRI customer service

.

_____________________________________________________________________

ERROR CODE D0900

Teach data is broken.

The program storage area of the system memory is damaged and is not linking data
correctly.

Main causes include:
1. Loss of memory battery back-up.
2. Noise related malfunction.
3. Defective 1KA board.

⇒

Set the 1KA board switch SW2-8 to ON and initialize the memory, do not use AUX
0805 or SYSINIT command. Reload the robot program data.

⇒

Check the memory backup battery. Replace if necessary (3.3 VDC or less). When
battery voltage drops to 3.3 VDC, or less, error W1010 is displayed.

⇒

Replace the 1KA board if the error recurs.

_____________________________________________________________________