Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 71

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-68

August 9, 2005

Ka a a

w s k

ERROR CODE E1013

InterBus board is not installed.

The 1JF board is not installed.

⇒

Ensure the 1JF board is properly installed

.

⇒

Replace the 1JF board.

_____________________________________________________________________

ERROR CODE E1016

No. XX CC-LINK board is not installed.

The specified number 1HS board is not installed.

⇒

Installed the specified number 1HS board.

⇒

Ensure the specified number 1HS board is properly installed.

⇒

Replace the specified number 1HS board.

_____________________________________________________________________

ERROR CODE E1017

PLC error. Error code is Hex. XX.

This error occurs when a PC3JB (TOYOPUC) internal error is present (program memory
check sum error, parameter setting error, etc.).

⇒

Refer to the PC3JB (TOYOPUC) manual for the code (Hex. XX).

⇒

Replace the PC3JB (TOYOPUC).

_____________________________________________________________________

ERROR CODE E1018

INTER-BUS status error.

A processing error such as cable disconnection is detected at the 1JF board during
communication.

⇒

Refer to the 1JF board manual for information for checking error state displayed by
the front LED

.

⇒

Replace the 1JF board.

_____________________________________________________________________

ERROR CODE E1020

External equipment is abnormal.

An abnormality in peripheral equipment is detected by the PC3JB board

(TOYOPUC).

⇒

Check PC3JB board (TOYOPUC) peripheral equipment connections.

⇒

Ensure proper installation and connection of peripheral equipment.

_____________________________________________________________________

Advertising