TROUBLESHOOTING

1-181

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE P2000

Turn OFF motor power.

An attempt is made to execute an operation or command which is not permitted with
motor power ON.
Example: ZZERO command.

⇒

Turn motor power OFF and re-execute operation or command.

_____________________________________________________________________

ERROR CODE P2001

Turn HOLD/RUN sw. to HOLD.

Occurs when an attempt to execute DO, STEP, MSTEP, CONTINUE, or EXECUTE
command is made with the RUN/HOLD switch in the RUN position. Only applies if the
CHECK.HOLD system switch is ON (AUX 0502).

⇒

Turn the RUN/HOLD switch to HOLD position.

_____________________________________________________________________

ERROR CODE P2002

There is no external axis.

External axis cooperative motion command is executed and external axis equipment is
not installed.

⇒

Enable option or contact customer service to install external axis option.

_____________________________________________________________________

ERROR CODE P2003

Illegal positioner type.

An out of range value is used to specify the type of positioner for an external axis.

⇒

Specify the positioner type with a value that is in range.

_____________________________________________________________________

ERROR CODE P2004

Cannot change, user data already exist.

An attempt is made to change system data (number of axes, etc.) without deleting
existing user data.

⇒

Save user data to PC card or floppy disk and delete user data from system memory.
Change system data and reload user data from PC card or floppy disk.

_____________________________________________________________________