Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 79

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-76

August 9, 2005

Ka a a

w s k

ERROR CODE E1031

Miscount of encoder data (Jt XX).

The servo gun or tool changer harness is defective.

⇒

Inspect the servo gun and tool changer harnesses; replace if necessary.

_____________________________________________________________________

ERROR CODE E1032

Mismatch ABS and INC encoder data (Jt XX).

Occurs when there is a large difference between the value in the serial encoder data
and the calculated data using the incremental technique.

Power
circuit

Battery

Encoder

Encoder

1FG/1HG board

Robot

Controller

1KB board

Encoder I/F

Servo

CPU

Encoder +12 VDC power supply

Main causes include:
1. Defective encoder or encoder harness.
2. Defective 1KB board.
3. Noise related malfunction.
4. Defective 1FG/1HG board.
5. Servo spot weld gun.

–Loose connection at tool changer.
–Defective tool changer harness.

⇒

Replace encoder, replace 1KB board.

⇒

Check connections at encoder, 1FG/1HG board, and separation harness.

⇒

Ensure the 1KB board is properly seated into the card rack.

⇒

Check for continuity in the machine harness and separation harness.

⇒

Check for noise and shield integrity.

⇒

Replace 1FG/1HG board.

For additional information on error code E1032, see section 1.4.

_____________________________________________________________________