Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 46

Advertising
background image

TROUBLESHOOTING

1-43

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE D1517

Blown fuse on safety circuit emergency line.

Fuse F1 on the 1KP board is open.

Main causes include:
1. Incorrect wiring in the emergency line (wiring harness, emergency stop, safety fence,

external trigger, teach pendant, limit switches).

2. Short-circuit in the emergency line (wiring harness, emergency stop, safety fence,

external trigger, teach pendant, limit switches).

3. Defective 1KP board.

⇒

Check wiring and components in the safety circuit emergency line and repair/replace
as necessary

.

⇒

Replace 1KP board.

⇒

Ensure the controller power is set OFF, when wiring safety circuits. The fuse F1 will
blow if wiring is shorted.

_____________________________________________________________________

ERROR CODE D1518

Mismatch in the Emer. Stop condition safety circuit.

Main causes include:
1. When the system is set for double safety circuits, and the circuits at the operation

panel, teach pendant, and/or the external emergency stop switch are wired as single
circuits.

2. Disconnection or ground fault in the emergency stop circuit.
3. Defective 1KP board.

⇒

With the E-STOP switch(es) engaged, check wiring harness and switches in the
circuit and repair or replace as necessary

.

⇒

Ensure all contacts in the external emergency stop circuit are wired correctly (double
circuits).

⇒

If the above steps do not correct the problem, replace the 1KP board.

_____________________________________________________________________

Advertising