Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 187

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-184

August 9, 2005

Ka a a

w s k

ERROR CODE P2016

Cannot open the file.

The file cannot be opened with the SAVE or LOAD commands.

⇒

Ensure the floppy disk is properly inserted into the floppy disk drive.

⇒

Ensure an existing file name is used.

⇒

Defective local bus harness.

⇒

Defective floppy disk, floppy disk drive unit, or 1KA board.

_____________________________________________________________________

ERROR CODE P2017

Cannot close the file.

A file opened by the SAVE or LOAD command cannot be closed.

⇒

If the file is opened using a PC, ensure proper connection with the controller.

⇒

Defective local bus harness.

⇒

Defective floppy disk, floppy disk drive unit, or 1KA board.

_____________________________________________________________________

ERROR CODE P2019

ADC function already in use.

This error occurs when a monitor command and a program command are executed for
an ADC function at the same time.

⇒

Do not execute a monitor command for an ADC function while a robot or process
control program is executing an ADC function command.

_____________________________________________________________________

ERROR CODE P2020

Illegal device number.

For Host Communication I, the sensor port is specified as logical device number 1 or 7.
The PC terminal port is specified as logical device number 2 or 8. This error occurs
when a SEND command/instruction specifies an illegal device number.
Example: SEND 3:$out,err.

⇒

Ensure an available device number is specified.

Example: SEND 1:$out,err.

_____________________________________________________________________