TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-116

August 9, 2005

Ka a a

w s k

ERROR CODE E4004

Communication retry error.

Communication retry error during Host Communication I.

Main causes include:
1. No response after sending text.
2. After text is sent, NAK (resend request) exceeded the allowed number of retries.

⇒

Ensure communication protocol used for Host Communication I is correct.

⇒

Check the communication cable and replace as necessary.

_____________________________________________________________________

ERROR CODE E4005

Communication process was stopped.

During Host Communication I, a stop monitor command (ABORT, PCABORT, etc.) is
executed during execution of SEND/RECEIVE.

⇒

Re-execute the EXECUTE, PCEXECUTE, etc. command.

_____________________________________________________________________

ERROR CODE E4006

Receive no data after request.

During Host Communication I, text data is not received within the allowed time after the
data request is sent.

⇒

Ensure communication protocol used for Host Communication I is correct.

⇒

Check the communication cable and replace as necessary.

_____________________________________________________________________

ERROR CODE E4007

Receiving data is too long (MAX=255 character).

During Host Communication I, an attempt to receive a string with more than 255 charac-
ters is made.

⇒

Ensure communication protocol used for Host Communication I is correct.

_____________________________________________________________________

ERROR CODE E4008

Abnormal data (EOT) received in communication.

During Host Communication I, abnormal code (EOT) is received and the communication
process is stopped.

⇒

Ensure communication protocol used for Host Communication I is correct.

_____________________________________________________________________