TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-174

August 9, 2005

Ka a a

w s k

ERROR CODE P1009

Program is already running.

Main causes include:
1. An attempt is made to edit or execute a program that is running.
2. SYSINIT command is executed while a program is running.

⇒

Stop the robot control program prior to editing or checking.

⇒

Stop the robot control program prior to executing the SYSINIT command.

_____________________________________________________________________

ERROR CODE P1010

Robot control program is already running.

Occurs when an attempt is made to execute a DO, TOOL, or BASE command when a
robot control program is running.

⇒

Wait for the robot control program to complete execution.

⇒

Stop the robot control program.

_____________________________________________________________________

ERROR CODE P1011

Cannot continue this program. Use EXECUTE.

After a program is executed the specified number of times in repeat mode, the CON-
TINUE command is entered or the CYCLE START switch is pressed.

⇒

The CONTINUE command or CYCLE START switch cannot be used at this time, use
the EXECUTE command to start the program.

⇒

Re-select the program and press the CYCLE START switch.

_____________________________________________________________________

ERROR CODE P1012

Robot is moving now.

Displayed if any of the following commands are entered while a program is running:
EXECUTE, CONTINUE, TOOL, BASE, DO. SYSINIT or CYCLE START.

⇒

Stop the program or confirm the operation to be performed.

_____________________________________________________________________

ERROR CODE P1013

Cannot execute because in error now. Reset error.

Occurs when attempt is made to start robot motion before an error has been cleared.

⇒

Clear any errors and re-enter the command.

_____________________________________________________________________