TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-136

August 9, 2005

Ka a a

w s k

ERROR CODE E5024

Pressurization comp. signal has not been detected.

Pressurization completion signal is not received from the weld controller/timer.

Main causes include:
1. Defective weld controller/timer.
2. Defective servo spot weld gun.
3. Defective harness, cable, etc.

⇒

Check weld controller/timer, servo spot weld gun, harnesses, and cables and repair/
replace as necessary

.

_____________________________________________________________________

ERROR CODE E5025

Gun opening comp. signal has not been detected.

Gun opening completion signal is not received from the servo weld gun.

Main causes include:
1. Defective servo spot weld gun.
2. Defective servo spot weld gun cable, cable connections, tool changer, etc.

⇒

Check the servo spot weld gun, servo spot weld gun cable, cable connections, and
tool changer contacts and connections and repair/replace as necessary.

_____________________________________________________________________

ERROR CODE E5026

RWC error -xx.
(Spot weld specifications type B)
(-xx: represents the welder number)

The current flow from the specified remote weld controller (RWC) Is abnormal.

Main causes:
20: SCR overheat

21: Memory abnormal

22: Power failure

23: System error

24: Defective electro-valve (gun control valve)

Main causes include:
Insufficient SCR cooling, a memory data error, weld current is not synchronized with gun
clamp conditions, system error, or gun control valves malfunction.

⇒

Check welder and weld gun repair/replace as necessary.

⇒

Check 1GS board, and communication cables repair/replace as necessary.

_____________________________________________________________________