NT5D97 Dual-port DTI2/PRI2 installation and removal

Receiver impedance

A per-trunk set of four DIP switches (S8/S14 provides selection between
75 or 120 ohm values. Refer to

Table 41 "Trunk interface impedance switch

settings" (page 132)

.

Table 41
Trunk interface impedance switch settings

Description

S8/S14 switch setting

75 ohm

OFF

OFF

ON

OFF

120 ohm

OFF

OFF

OFF

ON

Ring ground switches for NT5D97AA/AB

A set of four DIP switches (S2) selects which Ring lines are connected to
the ground. Refer to

Table 48 "LBO switches for NT5D97AD" (page 136)

.

Table 42
Ring ground switch settings

Switch

Description

S2 switch settings

1

Trunk 0 Transit

OFF-Ring line is not grounded
ON- Ring line is grounded

2

Trunk 0 Receive

OFF-Ring line is not grounded
ON- Ring line is grounded

3

Trunk 1 Transmit

OFF-Ring line is not grounded
ON- Ring line is grounded

4

Trunk 1 Receive

OFF-Ring line is not grounded
ON- Ring line is grounded

DCH Address select switch for NTBK51AA daughter board for
NT5D97AA/AB

In case of an onboard NTBK51AA D-channel daughterboard, a set of four
switches (S3) provide the daughterboard address. Refer to

Table 50 "Trunk

1 switches" (page 137)

.

Note: Switch 8 of S3 (S3-8) does not require a switch setting to
select between the onboard NTBK51AA D-channel daughterboard
and an external DCHI/MSDL. The NT5D97 detects when the onboard
NTBK51AA D-channel daughterboard is used.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007