Ld 16 - configuring a dti trunk – Nortel Networks NN43001-301 User Manual

Page 224

Advertising
background image

224

1.5 Mb DTI implementation

4

Assign clock’s reference source. See

"LD 73 - Assigning a clock

reference source" (page 225)

.

—End—

LD 17 - Adding a DTI card

Prompt

Response

Description

REQ

CHG

Change existing data.

TYPE

CFN

Configuration data block.

...

PARM

YES

...

PCML

(MU) A

System PCM law.
Default is MU law.

...

CEQU

YES

Changes to common equipment.

DLOP

ll dd ff

Digital Trunk Interface Loop or Loops

MODE

TRK

Select Digital Trunk Interface mode.

TMDI

(YES) NO

Whether the card is a TMDI card.

YALM

DG2 (FDL)

Yellow alarm method — prompted only if the frame format
is ESF — Must match the far end.

Use FDL with ESF and use DG2 with non-ESF. If not
prompted then DG2 is set automatically.

TRSH

0-15

The maintenance and threshold table to be used for this
DTI card, as configured in LD 73.

T1TE

0 1 2

T1 Transmit Equalization (0=0-200 ft., 1=200-400 ft,
2=400-700 ft). Only for TMDI = YES.

LD 16 - Configuring a DTI trunk route

Prompt

Response

Description

REQ

NEW
CHG

Add new data.
Change existing data.

TYPE

RDB

Route data block.

TKTP

Create a trunk route.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.