Nortel Networks NN43001-301 User Manual

Page 32

Advertising
background image

32

ISDN Primary Rate Interface equipment overview

Faceplate destination

Type

J2

9-pin female, D-connector

J3

36-pin connector

J4

15-pin male, D-connector

J5

15-pin male, D-connector

J6

15-pin female, D-connector

RCV MON

Miniature bantam jack

XMT MON

Miniature bantam jack

QPC720 Cable requirements

Table 5 "QPC720 PRI cables and cable lengths" (page 33)

lists the types of

cable used and the lengths required for external QPC720 PRI connections.

Note: No additional cabling is required for nB+D configurations. Multiple
PRIs and the D-channel are associated through software in LD 17,
prompt PRI.

Carrier interface

The QPC720 PRI provides an interface to the DS-1 Channel either directly,
through an office repeater, or through an Echo Canceller.

The T1 Channel Service Units listed below are compatible with the QPC720
PRI card and the 64K Clear Data feature as well as with PRI connection
parameters such as the Superframe format, the Extended superframe
format, and the B7 and B8ZS Alternate Mark Inversion (AMI) line coding.

Digital Link 551A

Digital Link 551C

Digital Link 551E

Tellabs Model 441

Verilink Model 551V ST

In the U.S.A., FCC Part 68 regulations require Network Channel Terminating
Equipment (for example, the NT QRY551 Channel Service Unit) installed
at of the point of connection between a system and a registered common
carrier trunk.

Echo Canceller interface

Echo Cancellers are required only with satellite transmission. The Echo
Canceller detects the length of the loop, then cancels the reflected
transmission (callers do not hear their own voices echoed).

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising