2.0 Mb PRI implementation

For the U.K., use DPNSS1 mode. For all other countries, use Q.931 mode.

Table 98
Switch SW1

Switch

Down (On)

Up (Off)

SW 1-1

SW 1-2

DPNSS1/DASS2

Q.931

Switch SW2 - Carrier impedance configuration

This switch sets the carrier impedance to either 120

1

/

2

or 75

1

/

2

. Twisted pair

cable is usually associated with 120

1

/

2

. Coaxial cable is usually associated

with the 75

1

/

2

setting.

Table 99
Switch SW2

Cable type

SW 2-1

75

3

/

4

Down (On)

120

3

/

4

Up (Off)

Switch SW4 - Carrier shield grounding

This switch supports the selective grounding of Tx and Rx pairs of carrier
cable. Closing the switch (down position) applies Frame Ground (FGND) to
the coaxial carrier cable shield, creating a 75

1

/

2

unbalanced configuration.

This applies only to the NTBK05CA cable.

Table 100
Switch SW3

Switch

Down (On)

Up (Off)

SW 4-1

Rx—FGND

Rx—OPEN

SW 4-2

Tx—FGND

Tx—OPEN

Note: The usual method is to ground the outer conductor of the receive
coax signal.

Mount the daughterboards on the NTBK50

Use the following procedure to mount and remove the NTAK20 CC and the
NTBK51 DDCH or NTAK93 DCHI daughterboards onto the NTBK50 PRI.

Install the NTAK93 or NTBK51 daughterboard before the NTAK20
daughterboard. Work on a flat surface when mounting or removing
daughterboards.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007