Clock Controller description and installation

SW1

SW2

SW4

System

1

2

3

4

1

2

3

4

1

2

3

4

*Cable length between the
J3 faceplate connectors:

0–4.3 m (0–14 ft)

off

off

4.6–6.1 m (15–20 ft)

off

on

6.4–10.1 m (21–33 ft)

on

off

10.4–15.2 m (34–50 ft)

on

on

*

If there is only one clock controller card in the system, set to OFF. If there are two clock
controller cards, determine the total cable length between the J3 connectors (no single cable
can exceed 25 ft.) and set these two switch positions for this cable length, as shown above. The
maximum total (combined) length is 50 ft. Set the switches on both cards to the same settings.

**

Set to ON for clock controller 0. Set to OFF for clock controller 1.

Note: FNF based-systems the total clock path length is equal to the length of the NTRC49 cable
used to connect between the two clock controller cards.

Table 66
Clock Controller switch settings for QPC775

System

SW2

SW3

SW4

Half Group, Single Group

ON

OFF

ON

Multi Group

OFF

OFF

ON

Table 67
Clock Controller switch settings for NTRB53

Multigroup/

Single group

Machine

Type # 1

Faceplate

Cable Length

(CC to CC)

Side Number

Machine

Type #2

1

2

3

4

5

6

Multigroup

= Off

Single group =
On

61, 51C, 61C

71, 81, 81C

= On

Off

Off

0-14 ft

Side 0 = On

Side 1 = Off

81 = Off

51, 51C

61, 61C, 81C =
On

Off

On

15-20 ft

On

Off

21-33 ft

On

On

34-50 ft

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007