NT5D12 Dual-port DTI/PRI card installation

Table 56
Trunk interface transmission mode switch settings

Description

S4/S10 Switch Setting

For future use.

OFF

T1

ON

Line Build Out

A per-trunk set of three switches provides a selection between 0, 7.5 or 15
dB values. See

Table 57 "Trunk interface line build out switch settings"

(page 146)

.

Table 57
Trunk interface line build out switch settings

Description

Switch Setting

S5/S11

S6/S12

S7/S13

0 dB

OFF

OFF

OFF

7.5 dB

ON

ON

OFF

15 dB

ON

OFF

ON

Receiver Impedance

A per trunk set of four DIP switches provides a selection between 75, 100
or 120

values. See

Table 58 "Trunk interface receiver impedance switch

settings" (page 146)

.

Table 58
Trunk interface receiver impedance switch settings

Description

S8/S14 Switch Setting

75

OFF

OFF

ON

OFF

100

ON

OFF

OFF

ON

120

OFF

OFF

OFF

ON

Ring ground switches

A set of four DIP switches selects which Ring lines are connected to the
ground. See

Table 59 "Ring ground switch settings" (page 147)

.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007