Install the NTBK50 PRI card

271

If more than one NTBK50 card is installed, the additional cards may not
carry daughterboards, depending on system configuration. At least one
NTAK20 (per system) is always required.

Insert the NTBK50

Slide the circuit card into card slot 1-9 in the Small System main cabinet,
or in slots 11-19, 21-29, 31-39, 41-49 of the first, second, third, and fourth
IP expansion cabinets, respectively.

Secure the circuit card in the cabinet by locking the lock latch assemblies.
The card number associated with a 2.0 Mb PRI card is based on the slot in
which the card is installed.

Connect the cables

Follow the instructions below to connect cables to the NTBK50 PRI card.
Also refer to

Figure 87 "NTBK50 cabling" (page 271)

.

In the cabling area, located directly below the card cage, remove the
retaining bar that secures the MDF cables. Connect the NTBK05DA/CA
interface cable to the 50-pin Amphenol connector below the slot in
which the NTBK50 is installed. reinstall the retaining bar to secure the
cable(s) in place.

Terminate the NTBK05DA/CA carrier cable as required.

Figure 87
NTBK50 cabling

NTBK05DA pinouts

The pinouts for the NTBK05DA cable are as follows:

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007