1.5 Mb PRI implementation

Prompt

Response

Description

- - PNI

(0) 1-32700

Private Network Identifier. Each customer data block must
have a unique PNI when multi-customer option is equipped.
PNI = 1 is typical for CUST = 0. It must be matched by
the PNI in the far-end RDB.

Note: Using the default value of PNI = 0, prevents operation
of features like NRAG, NACD and NMS.

IFC

xx

Interface type.

- CHTY

BCH

Signalling type - prompted if DTRK is YES. D-channel
signalling for B-channels.

- CTYP

<CR>

Call Type. Enter the call type to be associated with the
outgoing route for direct dialing using the trunk access
code (instead of NARS access code).

See the Software Input Output Administration
(NN43001-611)
for a listing of possible responses.

- INAC

YES

Insert ESN Access Code based on NARS/BARS call
type for incoming calls on TIE routes only. If NARS is
equipped, this feature inserts AC1 or AC2, depending on
the responses to AC2 in LD 15 Customer Data Block.

For NARS/BARS call types, INAC bypasses incoming digit
insertion specified by INST in LD 16 Route Data Block.

Unknown call types, including CDP steering codes, are
not affected by INAC, and do not bypass digit insertion
specified by INST.

INAC must be set to YES to support features such as
Network ACD and Network Message Services, which
depend on non-call associated TCAP facility messages.

LD 14 - Defining service channels and PRI trunks

Prompt

Response

Description

REQ

NEW
CHG

Add new data.
Change existing data.

When assigning several members at once use the multiple
create command NEW XX.

TYPE

TIE

TIE Trunk only, allowed between MSL-1.

TN

l ch

Loop and channel for digital trunks

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.