Figure 39 "qpc757 option and, Table 27 – Nortel Networks NN43001-301 User Manual

Page 89

Advertising
background image

Install the QPC757 DCH

89

Figure 39
QPC757 option and PRI/ISL low-speed programming switch settings

Port address switch settings

Table 27 "D-channel port address switch settings for PRI" (page 89)

shows

the port address switch settings that apply to SW1, SW2 (the D-channel
port), SW3, and SW4.

Table 27
D-channel port address switch settings for PRI

Port Address Switch Settings

Port Number

J1

J2

SW1

SW2

SW3

SW4

0

1

Off

Off

Off

Off

2

2

Off

Off

On

Off

4

5

Off

On

Off

Off

6

7

Off

On

On

Off

8

9

On

Off

Off

Off

10

11

On

Off

On

Off

12

13

On

On

Off

Off

14

15

On

On

On

Off

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising