2.0 Mb PRI implementation

Prompt

Response

Description

PERS

ttt

Persistence Timer for Group II problems.
Enter 0-256 msec in increments of 2 msec. Default is 50
(=100ms).

CLRS

ttt

Clearance Timer for Group II problems. Enter 0 - 256 msec in
increments of 2 msec. Default is 50 (=100ms).

OOSC

nnn

Out-of-Service Counter.
Range for nnn of 0-255 with a default of 5.

LD 73 - Changing trunk pad category values

Prompt

Response

Description

REQ

CHG

Change data.

TYPE

PRI2

2.0 Mb PRI.

FEAT

PADS

PDCA

#

PAD table-0 is default and is hard coded.

The following prompts define the pad levels.

The receiving pad code is r and the transmission pad code is t. These entries have the range 0-15.
The pad values (in decibels) relating to these codes are shown after this table.

ONP

r t

On-premises extension.

DSET

r t

Meridian Digital set.
Prompted only if the 2.0 Mb Gateway feature is equipped.

OPX

r t

Off-premises extension.

DTT

r t

Digital TIE trunks.

SDTT

r t

Digital Satellite TIE trunks.

NTC

r t

Nontransmission compensated.

TRC

r t

Transmission compensated.

DCO

r t

Digital COT, FEX, WAT, and DID trunks.

VNL

r t

Via Net Loss.

DTO

r t

2.0 Mb PRI2 digital TOLL office trunks.

ACO

r t

Analog CO or WATS trunks.

AFX

r t

Analog FEX trunks.

ADD

r t

Analog DID trunks.

SATT

r t

Analog satellite TIE trunks.

ATO

r t

Analog TOLL office trunks.

PRI2

r t

2.0 Mb PRI trunk.
Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=2.0 Mb PRI.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.