Table 103 pad values – Nortel Networks NN43001-301 User Manual

Page 281

Advertising
background image

PRI software implementation

281

Prompt

Response

Description

XUT

r t

Analog CO trunk.
Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=PRI2.

XEM

r t

Analog TIE trunk.
Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=PRI2.

Table 103 "Pad values" (page 281)

shows the pads available to 2.0 Mb PRI.

Positive dB represents loss and negative dB represents gain.

Table 103
Pad values

code

0

1

2

3

4

5

6

7

value
(dB)

0.0

+1.0

+2.0

+3.0

+4.0

+5.0

+6.0

+7.0

code

8

9

10

11

12

13

14

15

value
(dB)

+8.0

+9.0

+10.0

+11.0

+12.0

+13.0

+14.0

-1

code

16

17

18

19

20

21

22

23

value
(dB)

-2

-3

-4

-5

-6

-7

-8

-9

code

24

25

26

value
(dB)

-10

idle

+0.6

Configure DPNSS1 with IP expansion cabinets/Media Gateway systems

For Small Systems, when configuring a PRI2 card slot number for DPNSS1,
the response to the DDCS prompt in LD 17 is: 1-9 (Option 11C Cabinet),
11-19 (IP expansion cabinet 1), 21-29 (IP expansion cabinet 2), 31-39 (IP
expansion cabinet 3), 41-49 (IP expansion cabinet 4).

Configure ISDN BRI trunking with IP expansion cabinets/Media Gateway
systems

For Small Systems, when configuring the MISP card slot number for ISDN
BRI trunking in LD 27, the response to the LOOP prompt is: 1-9 (Option
11C Cabinet), 11-19 (IP expansion cabinet 1), 21-29 (IP expansion cabinet
2), 31-39 (IP expansion cabinet 3), 41-49 (IP expansion cabinet 4).

For Small Systems, when configuring the DSL for ISDN BRI trunking in
LD 27, the response to the MISP prompt is: 1-9 (Option 11C Cabinet),
11-19 (IP expansion cabinet 1), 21-29 (IP expansion cabinet 2), 31-39 (IP
expansion cabinet 3), 41-49 (IP expansion cabinet 4).

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning