Install PRI hardware

213

LD 17 - Adding a D-channel interface

Prompt

Response

Description

REQ

CHG

Change existing data.

TYPE

ADAN

Action Device And Number.

- ADAN

NEW DCH xx
CHG DCH xx
OUT DCH xx

Add a primary D-channel (any unused SDI port.)
Change a primary D-channel.
Remove the primary D-channel, where:
xx =0-79.

- CTYP

DCHI

MSDL

TMDI

DCHI = D-channel configuration for the NTAK09 card or
NTAK93.

MSDL = NTBK51 Downloadable D-channel daughterboard.

TMDI = D-channel configuration on TMDI (NTRB21) card.

- CDNO

1-50

Card slot number to be used as the primary DDCH/DCHI.

Card slots 10, 20, 30, 40, and 50 are only applicable for
D-channel configuration of ISL or VNS.

- PORT

1

PORT must be set to 1.

- DES

<CR>

Designator.

- USR

PRI

D-channel is for ISDN PRI only.

- IFC

xx

Interface type.

- - DCHL

xx

PRI loop number.

- OTBF

1-(16)-127

Number of output request buffers.

Note: For a single PRI link, leave this prompt at default (16).
Add 5 output request buffers per additional link.

- DRAT

64KC

D-channel transmission rate.

- SIDE

NET (USR)

Prompted only if IFC is set to SL1.
NET = network, the controlling switch.
USR = slave to the controller.

- RLS

xx

Release ID of the switch at the far-end of the D-channel.

- RCAP

ND2

Remote capability.

- OVLR

YES (NO)

Allow or disallow overlap receiving on a D-channel. Default
is NO. Enter carriage return if settings are to be left at
default.