DCH installation

D-channel parameter downloading

The system software automatically downloads new parameters to each
D-channel Interface (DCHI) circuit card upon SYSLOAD. When this occurs,
the D-channel is temporarily disabled and then automatically reenabled.

Three situations require manual disabling and enabling of each DCHI to
ensure parameter downloading:

Performing a parallel load and switching over to the second CPU

Following an alarm condition for the T1 loop carrying the D-channel (but
the D-channel is still operational)

Following SYSLOAD when using ISDN Signaling Link (ISL)

Remove the QPC757 DCHI

Use

Procedure 4 "Remove the QPC757 DCH" (page 90)

to remove the

QPC757 DCHI card from Large Systems.

CAUTION

The QPC757 DCH must be software disabled before it is hardware
disabled to prevent initialization

Procedure 4

Remove the QPC757 DCH

Step

Action

1

Disable the QPC757 DCHI using LD 96, command DIS DCH x.

2

Disable asynchronous port J1 in LD 48 to prevent initialization.

3

Disable loop in LD 60.

4

If the circuit card is being removed, not replaced, remove data from
memory.

5

Determine the cabinet and shelf location of the card to be removed.

6

Set faceplate toggle switch to DISABLE.

7

Disconnect QPC757 DCHI cables.

8

Remove QPC757 DCHI card.

9

Pack and store circuit card.

—End—