Install the NT5D97 DDP2

Use

Procedure 14 "Install the NT5D97 on Large Systems" (page 139)

to

install the NT5D97 on Large Systems.

CAUTION

The static discharge bracelet located inside the cabinet must be
worn before handling circuit cards. Failure to wear the bracelet
can result in damage to the circuit cards.

Procedure 14

Install the NT5D97 on Large Systems

Step

Action

1

Determine the cabinet and shelf location where the NT5D97 is to
be installed. The NT5D97 can be installed in any card slot in the
Network bus.

2

Unpack and inspect the NT5D97and cables.

3

If a DDCH is installed, refer to the section

"NTBK51 DDCH

installation and removal" (page 91)

.

4

Set the option switches on the NT5D97 card before installation.
Refer to

"NT5D97AA/AB DIP switch settings" (page 129)

.

The ENB/DIS (enable/disable faceplate switch) must be OFF (DIS)
when installing the NT5D97, otherwise a system initialize can occur.
The ENB/DIS on the NT5D97 corresponds to the faceplate switch
on the QPC414 Network card.

5

Install NT5D97 card in the assigned shelf and slot.

6

Set the ENB/DIS faceplate switch to ON.

If the DDCH is installed, the DDCH LED should flash three times.

7

If required, install the I/O adapters in the I/O panel.

8

Run and connect the NT5D97 cables