Table 82 ntak02 switch setting, Table 83 ntak02 jumper settings, Procedure 37 installing isl hardware – Nortel Networks NN43001-301 User Manual

Page 230: Procedure 37, Installing isl hardware

Advertising
background image

230

1.5 Mb ISL implementation

The NTAK02 connects to a modem via the NTAK19BA four-port cable. Only
ports 1 and 3 are available for use as DCHIs.

Procedure 37

Installing ISL hardware

Step

Action

1

Set option switches/jumpers on the NTAK02 card as shown in

Table

82 "NTAK02 switch setting" (page 230)

and

Table 83 "NTAK02

jumper settings" (page 230)

for mode of operation (RS232 or RS422

and DTE or DCE.)

Table 82
NTAK02 switch setting

Port 0

Port 1

SW 1-1

SW 1-2

SDI

DCH

OFF

OFF

SDI

DPNSS

OFF

ON

ESDI

ON

ON

Port 2

Port 3

SW 1-3

SW 1-4

SDI

DCH

OFF

OFF

SDI

DPNSS

OFF

ON

ESDI

ON

ON

Table 83
NTAK02 jumper settings

Unit

Jumper location

Strap for DTE

Strap for DCE

Unit 0

J10

C - B

B - A

Unit 1

J7
J6

C - B
C - B

B - A
B - A

Unit 2

J5

C - B

B - A

Unit 3

J4
J3

C - B
C - B

B - A
B - A

Unit

Jumper location

RS422

RS232

Unit 0

Unit 1

J9
J8

C - B
C - B

B - A
B - A

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.