Table 78 ntak09 switch settings, Table 78 – Nortel Networks NN43001-301 User Manual

Page 221

Advertising
background image

Install DTI hardware

221

Table 78
NTAK09 switch settings

Distance to digital
crossconnect

1
DCH F/W

2
(LEN 0)

3
(LEN 1)

4
(LEN 2)

0 - 133 feet

Off

Off

Off

On

133 - 266 feet

Off

On

On

Off

266 - 399 feet

Off

Off

On

Off

399 - 533 feet

Off

On

Off

Off

533 - 655 feet

Off

Off

Off

Off

Connect the cables

For Small Systems, connect the NTBK04 cable to the 50-pin amphenol
connector below the card slot in which the NTAK09 circuit card is installed.
Connect the other end of the cable to the CSU or DSX-1 cross connect.

The NTBK04 is twenty feet long. If additional distance is required, the
NT8D97AX 50-foot extension is available up to a 600-foot maximum. The
only cable required to support the NTAK09 circuit card is the NTBK04.

Pinout information on the NTBK04 cable is given in

Table 79 "DS-1 line

interface pinout for NTBK04 cable" (page 221)

.

Table 79
DS-1 line interface pinout for NTBK04 cable

From 50-pin
MDF connector

to DB-15

Signal
name

Description

pin 48

pin 1

T

transmit tip to network

pin 23

pin 9

R

transmit ring to
network

pin 25

pin 2

FGND

frame ground

pin 49

pin 3

T1

receive tip from
network

pin 24

pin 11

R1

receive ring from
network

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising