Nortel Networks NN43001-301 User Manual

Page 177

Advertising
background image

Installation procedures

177

LD 135

SCPU

Switch CPU

Note: Wait two minutes before proceeding to the next step.

CAUTION

The following procedure to faceplate disable the active
clock controller could impact service.

9

Disable the faceplate of the active clock controller to force the newly
installed clock controller to activate.

10

Disconnect the Clock-to-Clock faceplate cable to J3 of the new clock
controller card in the active CPU side

CAUTION

Active calls will experience noise over local and trunk calls

11

Verify that the clock controller is active. At the prompt, enter

LD 60

SSCK

Get status of the new system clock, where x = 0 or 1

TRCK PCK

Track primary clock, where x = 0 or 1

RCNT

Resets all alarm counters of all digital cards

****

Exit the overlay

Note: Replacing the clock controller will generate errors on the
network equipment. It is recommended that all counters be reset.

12

Replace the remaining QPC775 or QPC471 clock controller card,
tag and disconnect the cables to the card you are removing.

13

Unhook the locking devices on the card and pull it out of the card
cage.

14

Set the ENB/DIS switch to DIS on the replacement card.

15

Set the option switches on the replacement card (NTRB53). Refer to

Table 67 "Clock Controller switch settings for NTRB53" (page 170)

.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising