2.0 Mb DTI implementation

Task summary list

The following is a summary of the tasks in this section:

1.

"LD 17 - Adding a 2.0 Mb DTI card" (page 242)

2.

"LD 73 - Defining the 2.0 Mb DTI ABCD signaling bit tables" (page 242)

3.

"LD 73 - Defining the 2.0 Mb DTI pad tables" (page 246)

4.

"LD 73 - Defining the 2.0 Mb DTI timers" (page 249)

5.

"LD 73 - Defining the 2.0 Mb DTI system timers" (page 252)

6.

"LD 16 - Configuring the service routes" (page 253)

LD 17 - Adding a 2.0 Mb DTI card

Prompt

Response

Description

REQ

CHG

Change.

TYPE

CEQU

Common equipment.

...

DTI2

xx

Enter a card slot number for 2.0 Mb DTI.

LD 73 - Defining the 2.0 Mb DTI ABCD signaling bit tables

Prompt

Response

Description

REQ

NEW
CHG

Add or change Digital Trunk Interface data block.

TYPE

DTI2

2.0 Mb/s DTI data block.

FEAT

ABCD

ABCD bit signaling category.

SICA

2-16

Signaling category.

...

DFLT

(1)-16

Default signaling category used for default values

JDMI defaults to 16 with <CR>

3

.

Incoming/Outgoing Calls:

IDLE(S)

abcd

(Send) idle signal bits.

IDLE(R)

abcd

(Receive) idle signal bits.

FALT(S)

abcd

(Send) bits. 2.0 Mb DTI out-of-service.

N

If FALT (send) signal not required.

FALT(R)

abcd

(Receive) bits. 2.0 Mb DTI out-of-service.

N

If FALT (receive) signal not required.

Incoming Calls:

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.