After a repeated START condition, I

2

C-bus may switch to the Master Transmitter Mode.

11.6.3 Slave Receiver mode

In the Slave Receiver Mode, data bytes are received from a master transmitter. To
initialize the Slave Receiver Mode, the user should write the slave address to the Slave
Address Register (I2ADR) and the I

2

C Control Register (I2CON) should be configured as

follows:

CRSEL is not used for slave mode. I2EN must be set = 1 to enable I

2

C function. AA bit

must be set = 1 to acknowledge its own slave address or the general call address. STA,
STO and SI are cleared to 0.

After I2ADR and I2CON are initialized, the interface waits until it is addressed by its own
address or general address followed by the data direction bit which is 0(W). If the direction
bit is 1(R), it will enter Slave Transmitter Mode. After the address and the direction bit
have been received, the SI bit is set and a valid status code can be read from the Status
Register(I2STAT). Refer to

Table 76

for the status codes and actions.

Fig 33. Format of Master Receiver mode.

S

R

A

slave address

logic 0 = write

logic 1 = read

from Master to Slave

from Slave to Master

A = acknowledge (SDA LOW)
A = not acknowledge (SDA HIGH)
S = START condition

002aaa930

DATA

DATA

data transferred

(n Bytes + acknowledge)

A

A

P

Fig 34. A Master Receiver switches to Master Transmitter after sending Repeated Start.

S

R

A

SLA

logic 0 = write

logic 1 = read

from Master to Slave

from Slave to Master

002aaa931

DATA

DATA

data transferred

(n Bytes + acknowledge)

A

W

A

SLA

DATA

A

P

A

RS

A = acknowledge (SDA LOW)
A = not acknowledge (SDA HIGH)
S = START condition
P = STOP condition
SLA = slave address
RS = repeat START condition

Table 72.

I

2

C Control register (I2CON - address D8h)

Bit

7

6

5

4

3

2

1

0

-

I2EN

STA

STO

SI

AA

-

CRSEL

value

-

1

0

0

0

1

-

-