8-2-3. Check Code List (Outdoor)

¡

: Go on,

¥

: Flash,

l

: Go off

ALT (Alternate): Alternate flashing when there are two flashing LED SIM (Simultaneous): Simultaneous flashing when there are two flashing LED

²

When this warning was detected before group construction/address check finish at power supply was turned on, the mode shifts automatically to AUTO address setup mode.

Remote

controller

indication

F04

F06

F08
F07
F12
F13
F15
F31

H01

H02
H03
H04

L10

L29

P03

P04

P05
P07
P15
P20
P22
P26
P29

E01

E02

E03

E04
E08

E09

E10

E18

L03
L07
L08
L09
L30

P19

Sensor lamp part

Block indication

Operation Timer Ready Flash

¥

¥

¡

ALT

¥

¥

¡

ALT

¥

¥

¡

ALT

¥

¥

¡

ALT

¥

¥

¡

ALT

¥

¥

¡

ALT

¥

¥

¡

ALT

¥

¥

¡

SIM

l

¥

l

l

¥

l

l

¥

l

l

¥

l

¥

¡

¥

SIM

¥

¡

¥

SIM

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

¥

ALT

¥

l

l

¥

l

l

¥

l

l

l

l

¥

¥

l

l

¥

l

l

¥

l

l

¥

l

l

¥

l

¥

SIM

¥

l

¥

SIM

¥

l

¥

SIM

¥

l

¥

SIM

¥

¡

¥

SIM

¥

l

¥

ALT

Representative defective position

Outdoor unit Discharge temp. sensor (TD) error

Outdoor unit Temp. sensor (TE, TS, TL) error

Outdoor unit Outside temp. sensor (TO) error
Outdoor unit Temp. sensor (TL) error
Outdoor unit Temp. sensor (TS) error
Outdoor unit Temp. sensor (TH) error
Outdoor unit Misconnection of temp. sensor (TE, TS)
Outdoor unit EEPROM error

Outdoor unit Compressor break down

Outdoor unit Compressor lock
Outdoor unit Current detection circuit error
Outdoor unit Case thermostat operation
Outdoor unit Setting error of service P.C. board type

Outdoor unit Other outdoor unit error

Outdoor unit Discharge temp. error
Outdoor unit

High pressure system error, Power supply voltage error
Power supply error
Outdoor unit Heat sink overheat
Gas leak detection
Outdoor unit High pressure system error
Outdoor unit Outdoor fan error
Outdoor unit Inverter Idc operation
Outdoor unit Position detection error
No remote controller master unit

Remote controller communication error

Remote controller send error

Regular communication error between indoor and

remote controller
Indoor/Outdoor serial error
Duplicated indoor addresses

²

Duplicated main remote controllers

Communication error between CPU
Regular communication error between header and

follower indoor units
Duplicated indoor header units

²

There is group cable in individual indoor unit.

²

Unset indoor group address

²

Unset indoor capacity
Outside error input to indoor unit (Interlock)

4-way valve inverse error

Detection

Outdoor

Outdoor

Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor

Outdoor
Outdoor
Outdoor
Outdoor

Outdoor

Outdoor

Outdoor

Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor

Remote

controller

Remote

controller

Indoor

Indoor
Indoor

Remote

controller

Indoor

Indoor

Indoor
Indoor
Indoor
Indoor
Indoor
Indoor

Outdoor

Explanation of error contents

Open/Short of discharge temp. sensor was detected.
Open/Short of heat exchanger temp. sensor was detected.

Miswiring between TE sensor and TS sensor
Open/Short of outside temp. sensor was detected.
Open/Short of heat exchanger temp. sensor was detected.
Open/Short of suction temp. sensor was detected.
Open/Short of heat sink temp. sensor (Board installed) was detected.
Misconnection of outdoor heat exchanger temp. sensor and suction temp. sensor was detected.
Outdoor P.C. board part (EEPROM) error was detected.
When reached min-Hz by current release control, short-circuited current (Idc) after

DC excitation was detected.
Compressor lock was detected.
Current detection circuit error
Case thermostat operation was detected.
When outdoor service P.C. board was used, model type select jumper setting was inappropriate.
1) Defective parts on outdoor P.C. board (MCU communication, EEPROM, TH sensor error)

2) When outdoor service P.C. board was used, model type selection was inappropriate.

3) Other error (Heat sink abnormal overheat, gas leak, 4-way valve inverse error) was detected.
Error was detected by discharge temp. release control.
When case thermostat worked or High-pressure SW worked error was detected

by high release control from indoor/outdoor heat exchanger temp. sensor. Power supply voltage error
Power supply voltage error
Abnormal overheat was detected by outdoor heat sink temp. sensor.
Abnormal overheat of discharge temp. or suction temp. was detected.
Error was detected by high release control from indoor/outdoor heat exchanger temp. sensor.
Error (Over-current, lock, etc.) was detected on outdoor fan drive circuit.
Short-circuited protective operation of compressor drive circuit element (G-Tr /IGBT) worked.
Position detection error of compressor motor was detected.
Signal was not received from indoor unit.

Main remote controller was not set. (including 2 remote controllers)

Signal cannot be sent to indoor unit.

No communication from remote controller and network adapter

Serial communication error between indoor and outdoor
Same address as yours was detected.
In 2-remote controller control, both were set as master.

(Indoor header unit stops warning and follower unit continues operation.)
MCU communication error between main motor and micro computer

Regular communication was impossible between master and follower indoor units.

There are multiple header units in a group.
When even one group connection indoor unit exists in individual indoor unit
Indoor address group was unset.
Capacity of indoor unit was unset.
Abnormal stop by CN80 outside error input

In heating operation, error was detected by temp. down of indoor heat exchanger or temp. up ofTE, TS.

Automatic

Operation

reset

continuation

Ч

Ч

Ч

Ч

¡

¡

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

¡

Ч

¡

Ч

¡

Ч

Ч

¡
¡

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

Ч

¡

Ч

Advertising