Toshiba CARRIER RAV-SP300AT2-UL User Manual

Page 90

Advertising
background image

– 90 –

No.

…

Part name

Exchange of

electric parts

Procedure

1. Control P.C. board

1) Perform work of Detachment 1 of



and

„

.

WARNING

Never disassemble the inverter for 1 minute after

power has been turned off because an electric

shock may be caused.

2) Remove the connectors connected to the

control P.C. board.

(Indoor power supply, temperature sensors,

PMV coil, 4-way valve coil, compressor case

thermo, fan motor, reactor, pressure switch.)
∗ Unlock the lock of the housing part and then

remove the connectors.

3) Remove the lead wires connected to the control

P.C. board.

(Torque at tightening time: 1.47 ± 0.1N•m)

Compressor lead

U: CN200

Red

V: CN201

White

W: CN202

Black

Reactor lead

Relay connector: 2 positions

Remove the power wire from the power supply

terminal block.

(Torque at tightening time: 2.5 ± 0.1N•m)

4) Remove the earth wire from the control P.C.

board. (Truss B tight screw M4, 6 mm, 1 pc.)

5) Remove the fixing screws of the control P.C. board.

(Screw with collar for fixing element M3, 16 mm,

7 pcs. Pan S tight screw for fixing P.C. board M3,

20 mm, 1 pc.)

6) Remove the control P.C. board.

(Supporter: 5 positions)

NOTE:

It is difficult to take out it because of radiator grease

for heat sink.

7) Mount a new control P.C. board.

NOTE:

Do not forget to attach the aluminum plate (Q201) and

the insulating sheet (Q300).

(Applying a little of radiator grease at the rear surface

of the insulating sheet in advance to adhere to the

heat sink makes easy the work.)

Remarks

Control P.C. board

Control P.C. board

Insulating sheet

Insulating sheet
(Q300)

(Q300)

Aluminum plate

Aluminum plate
(Q201)

(Q201)

Radiator grease

Radiator grease

Control P.C. board

Insulating sheet
(Q300)

Aluminum plate
(Q201)

Radiator grease

PMV coil

PMV coil

Indoor power supply

Indoor power supply

4-way valve coil

4-way valve coil

Pressure
switch

Compressor
lead

Fan motor

Bundling band

Bundling band

(Reactor lead)

(Reactor lead)

Power supply terminal block

Power supply terminal block

Screw for fixing P.C. board

Screw for fixing P.C. board

Power supply terminal block

Screw for fixing P.C. board

Screw for fixing element (7 positions)

Compressor
case thermo.

PMV coil

Senser

Senser

Indoor power supply

4-way valve coil

Ground screw

Ground screw

Inter unit

Inter unit
cable

cable

Senser

Ground screw

Inter unit
cable

Bundling band

(Reactor lead)

Relay

Relay
connector

connector

Relay
connector