SIP–DECT OM System Manual Release 3.0

8 OM Management Portal (OMP)

Aastra

depl-1624/1.0

Page: 108 (241)

In the

Automatic DB import

panel enter the following:

1

Startup only

: Activate this option if the import should be started for an initial configuration.

2

Startup and periodically

: If this option is activated, the OMM tries to import the

configured database file during startup and at the configured time of day.

3

Time

: Enter the time, the import should be started.

Please note:

An automatic database import at a configured time recommends the time
synchronization with an NTP server. For NTP server configuration see chapter
9.5.4 and chapter 9.6.

4

Protocol

: To import a database from an external server select the preferred protocol. The

following protocols are supported: FTP, FTPS, HTTP, HTTPS, TFTP.

5

Server

: Enter the IP address or the name of the external server.

6

User name

,

Password

: If necessary, enter the account data of the server.

7

File

: Enter the path and file name which include the OMM database.

The database file for an automatic import has to be configured in an URL format like

{ftp|ftps|http|https}://[[user:password@]server]/[directory/]file

or

tftp://[server]/[directory/]file.To be available at OMM startup time and to allow an initial
configuration via automatic import, this URL has to be specified via DHCP (option 24, see
chapter 9.5.4) or the OM Configurator (see chapter 9.6). If such a URL is given by DHCP