AASTRA SIP-DECT (Release 3.0)- OM System Manual - Installation, Administration and Maintenance EN User Manual

Page 57

Advertising
background image

SIP–DECT OM System Manual Release 3.0

7 OMM Web Service

Aastra

depl-1624/1.0

Page: 57 (241)

The following parameters can be configured using the OMM web service:

General settings

Read-only community

: The SNMP community strings forms a password that is sent by

the SNMP management system when querying devices. The query is answered only if the
SNMP community string matches. You may use “public” as a default keyword for read-
only access.

System contact

: Enter a descriptive text that typically is displayed in the SNMP

management software.

Trap handling

Activate the checkbox behind the

Trap handling

section to enable this feature.

Trap community

: This community string is used if the SNMP agent informs the SNMP

management system about events (Traps).

Trap host IP address

: Enter the IP Address that the SNMP agent uses to send traps.

Further notes

The RFP needs an initial (one-time) OMM connection to receive its SNMP configuration.
In case of a reset, this configuration does not change. Changing the SNMP configuration
on the OMM forces all agents to be reconfigured.

The agent does not support MIB-II write access, SNMPv2-MIB read/write access, NET-
SNMP-MIB read/write access, NET-SNMP-AGENT-MIB read/write access and SNMPv3.

For background information on using SNMP with the SIP–DECT system please refer to
section 9.16.

Advertising