11 Appendix
Aastra
depl-1624/1.0
Page: 236 (241)
Protocol
IP-RFP
Server port
Client port
HTTP/HTTPS client
for the SIP–DECT
XML terminal
interface
tcp
80/443
> 1024
RFP control protocol
tcp client
16321
>=1024 (see note)
HTTP server (redirect
to OMM web server
(http))
tcp server
80 or as configured
any
SSH server
tcp server
22
any
DHCP client
udp
67
68
TFTP client
udp
69 / given by server
>=1024 (see note)
OMCFG server
udp
64000
64000
NTP client
udp
123
123
Syslog client
udp
514 or as configured
514
DNS client
udp
53
>=1024 (see note)
SNMP agent (server) udp
161
any
SNMP trap agent
(client)
udp
>=1024 (see note)
162
RSXport (debug only) tcp server
38477
any
RTP/RTCP (server)
udp
Range of [RTP port
base + 71] even ports
for RTP, odd ports for
RTCP. Port base is
16320 or as
configured.
any
RTP/RTCP (client)
udp
any
Range of [RTP port
base + 71] even ports
for RTP, odd ports for
RTCP. Port base is
16320 or as
configured.
Note:
Unbound ports start at port 1024.