5 capturing rfps, Capturing rfps – AASTRA SIP-DECT (Release 3.0)- OM System Manual - Installation, Administration and Maintenance EN User Manual

Page 71

Advertising
background image

SIP–DECT OM System Manual Release 3.0

7 OMM Web Service

Aastra

depl-1624/1.0

Page: 71 (241)

6 To read error hints in the referring log file, press the

Log file

button. Error hints can also

be read in a syslog trace (see chapter 7.4.1).

7 To remove imported data entries, activate the check box next to the desired entries. Press

Delete

to remove the selected entries.

7.6.5

Capturing RFPs

RFPs, which are assigned to the OMM by DHCP options or OM Configurator settings, may
plug to the system.

1 On the

Radio fixed parts

page press the

Start

button.

After a while the list page is filled by the MAC addresses of those RFPs which tried to
register to the OMM (unregistered RFPs).

Note:

Please note that these entries are not really stored (they are lost after reset).