2 data section fields, 3 example, Data section fields – AASTRA SIP-DECT (Release 3.0)- OM System Manual - Installation, Administration and Maintenance EN User Manual
Page 228: Example

SIP–DECT OM System Manual Release 3.0
11 Appendix
Aastra
depl-1624/1.0
Page: 228 (241)
11.7.2.2 Data Section Fields
The data section contains the following field order:
1 MAC address
2 Name
3 DECT activated
4 DECT cluster
5 Paging area (ignored by Web import and always set to “0”, PA0)
6 Preferred sync.
7 Reflective env.
8 Site ID (if left empty then set to the lowest Site ID)
9 Building (ignored by Web import and always set to “”)
10 Floor (ignored by Web import and always set to “”)
11 Room (ignored by Web import and always set to “”)
12 WLAN profile
13 WLAN antenna
14 WLAN channel
15 WLAN power
16 WLAN activated
11.7.2.3 Example
The following screenshot shows an RFP enrolment data import dialog that is shown if the
corresponding configuration file is imported.