Ieee 1284, Usb port – Printronix SL4M User Manual

Page 132

Advertising
background image

132

Chapter

4

INTERFACES Menu

Latch Data On

. Specifies whether the data is read on the leading or

trailing edge of the data strobe signal.

The options are Leading (factory default) and Trailing.

Prime Signal

Disable

(factory default). A prime signal from the host is ignored.

Enable

. A prime signal from the host resets the printer.

TOF Action

Reset

(factory default). If the printer is reset by a prime signal the

printer first moves to the next TOF.

Do Nothing

. If the printer is reset by a prime signal the printer will not

move to the next TOF.

Buffer Size in K

.

This option configures the amount of memory allocated

for the Ethernet buffer. The range is 1-16 Kbytes, in 1-Kbyte increments.

The factory default is 16 Kbytes.

IEEE 1284

Prime Signal

Disable

(factory default). A prime signal from the host is ignored.

Enable

. A prime signal from the host resets the printer.

TOF Action

Reset

(factory default). If the printer is reset by a prime signal the

printer first moves to the next TOF.

Do Nothing

. If the printer is reset by a prime signal the printer will not

move to the next TOF.

Buffer Size in K

.

This option configures the amount of memory allocated

for the Ethernet buffer. The range is 1-16 Kbytes, in 1-Kbyte increments.

The factory default is 16 Kbytes.

Offline Process

Disable

(factory default). When set to disable, the printer does not

process parallel/network data while offline.

Enable

. When set to enable, the printer continues to process (but not

print) the current network/parallel job while the printer is offline until
the printer's buffer is full.

USB Port

Buffer Size in K

. This option configures the amount of memory allocated

for the serial port buffer. The range is 1-16 Kbytes, in 1-Kbyte increments.

The factory default is 16.

Timeout

.

This item allows you to set the time that the printer, when it has

not received data from its host, will begin to service all other host ports
looking for data to print.

The range is 1-60 seconds, and the default is 10 seconds.