General Commands

265

Table 22. General PTX_SETUP Commands

Command

Sub-Command

Parameter

Description

CONFIG

LOAD

Cfg

Cfg

can be 0-8. The PTX_SETUP

will load configuration

Cfg

. If

configuration

Cfg

was not previously

saved, the operator panel will
display an error message and the
current configuration will be kept.

SAVE

Cfg

Cfg

must be 1-8. This command will

save the current configuration as
configuration

Cfg

. If

Cfg

is not in the

range of 1-8, the command is
ignored.

SETMENU

Value;Menu_tag

Menu_tag

is the name of the menu

as defined in the menu file.

Value

is

the value to which the menu is to be
set.

POWERUP

Cfg

Sets the power-up configuration to

Cfg

and loads Configuration

Cfg

.

Cfg

can be any value from 0-8,

where 0 is the factory default.

PRINT

Cfg

Print Configuration

Cfg

.

Cfg

can be

a number 1-8, or one of four pre-
defined configurations. The four
non-numeric configurations are
requested using the first character
for the CURRENT, FACTORY,
POWERUP, or ALL configuration(s).

DELETE

Cfg

Deletes Configuration number

Cfg.

Cfg

must be in the range of 1-8.

UPLOAD

Port;Cfg

This command uploads the
configuration stored in location

Cfg

to the port specified by

Port

.

Port

must either be 1284 or SERIAL.

Cfg

may be 1-8 or ALL.

DOWNLOAD

Cfg

This command saves the
configuration data that follows as
configuration

Cfg. Cfg

must be 1-8

or END.