Diagnostics for E0xx, Bad NVM, or ILL NVM Errors

E01A TYPE 0x40
E01B TYPE 0x60
E02 MACHINE CHK
E03A DSI HASH L
E03B DSI HASH S
E03C DSI BAT PL
E03D DSI BAT PS
E03E DSI CXIWX
E03F DSI CXOWX
E03G DSI ECXIWX
E03H DSI ECXOWX
E04A ISI NO TRA
E04B ISI DIRECT
E04C ISI PROTEC
E06 NOT ALIGNED
E07 ILLEGAL INS
E08 FLOATINGPNT
See User Manual

Yes

An illegal or
unsupported instruction
was attempted in the
application program.

1.

Cycle Power. Run the
print job again. If the
message appears, load
the latest emulation
software.

2.

Cycle power. Run the
print job again. If the
message appears,
record the display
message and follow the
instructions on
page 186.

3.

Contact your authorized
customer service
representative.

EMC NOT FOUND

PWR OFF PRINTER

Insert Cartridge

Yes

The printer does not
contain an EMC and
the firmware attempted
to access the EMC.

Install EMC or contact your
authorized service
representative.

ERROR: DC PROGRAM

NOT VALID

Yes/No

The printer cannot find
the data controller
program or the
validation checksum is
corrupt.

Power off the printer for 15
seconds, then power back
on. If the problem persists,
contact your authorized
customer service
representative.

ERROR: FLASH

DID NOT PROGRAM

Yes/No

The printer
encountered an error
trying to program flash
memory.

Power off the printer for 15
seconds, then power back
on. If the problem persists,
contact your authorized
customer service
representative.

Table 15. Fault Messages

Displayed Message

Can User

Correct?

Explanation

Solution

Advertising