Printer mgmt – Printronix SL4M User Manual

Page 138

Advertising
background image

138

Chapter

4

INTERFACES Menu

Framing Errors

. These are possible errors that can occur when serial

interface settings of the printer do not match those of the host computer.

Enable

(factory default). If a framing error occurs, a fault message

will display on the control panel.

Disable

. If a framing error occurs, a fault message will not display on

the control panel.

Offline Process

Disable

(factory default). When set to disable, the printer does not

process serial data while offline.

Enable

. When set to enable, the printer continues to process (but not

print) the current serial job while the printer is offline until the printer's
buffer is full.

Printer Mgmt

PNE Port

. This menu selects which port the printer expects PNE to

connect to, via Ethernet, USB, or Serial. The factory default is Disable.

Mgmt Protocol

.

Since PXML and UCP management protocols share the

same Ethernet Port, only one can be active at a time. This menu selects
the active Management Protocol Interface, either PXML or UCP. The
factory default is PXML.

Select Port

Debug

(factory default). If the PNE Port is set to Serial then the PNE

will communicate through the Debug Serial Port.

Host

. If the PNE Port is set to Serial then the PNE will communicate

through the Host Serial Port. This cannot be selected if Host Interface
is set to Auto Switching or Serial.

Table 12. ENQ Status Byte

Bit

Printer Status

0

Set when the label has printed.

1

Set when the label is presented.

2

Set while the printer is online.

3

Always set.

4

Set printing in the batch mode.

5

Set during a Ribbon fault.

6

Set during a Paper Out fault.

7

Set during a Head Open fault.

Advertising