MEDIA SETUP Submenus

81

Fault Reprint

This option determines how the printer handles data that was printing when
an error occurred.

Disable

(factory default). The printer will not reprint the label that was

printing when the error condition occurred.

Enable

. The printer reprints the label that was printing when the error

condition occurred.

NOTE:

When Fault Reprint is set to Enable and a RIBBON OUT condition
occurs, some labels may not reprint. This depends on the label
length, print speed selected, and the additional time it takes to detect
this condition. Be sure to verify that all labels were reprinted after a
RIBBON OUT condition by using the Ribbon Low indicator as
described on page 81.

Ribbon Low

When enabled, and the ribbon remaining on the supply spindle is less than

1/8 full, the Attention indicator will flash, and "Ribbon Low" displays on the last
line of the LCD. A Ribbon Low warning will not prevent printing.

The options are Disable (factory default) and Enable.

The Ribbon Low submenu is available if Admin User is set to Enable in the
PRINTER SETUP menu.

Units

This item selects either millimeters or inches as the unit of measure.

The options are In Inches (factory default) and In Millimeters.

Set Label Length

This feature selects whether the Sensed Distance value derived from an Auto
or Manual Calibrate will be used to set the Label Length value in the MEDIA
SETUP menu.

Manual

(factory default). The Sensed Distance value derived from an

Auto or Manual Calibrate

will not

override

or change the Label Length

value.

Automatic

. When an Auto or Manual Calibrate is performed, the Sensed

Distance value derived from either calibrate

will override

and change the

Label Length value. If no Auto or Manual Calibrate is performed, the
current Label Length value will be used.

NOTE:

When Set Label Length = Automatic and Gap/Mark Sensor = Gap,
the printer will subtract the Gap Length value (in the SENSOR
SETUP menu) from the Sensed Distance value obtained when the
Auto or Manual Calibrate was performed.

If you set the label length to Automatic, the Enable setting for Use
Label Length under the Sensor Setup menu will be ignored.