Baud Rate

. Sets the baud rate of the serial interface used to

communicate to the PNE. Baud rate is the speed at which serial data is
transferred between the PNE and the printer. The options for the RS-232
interface are 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and
115200 Baud.

Word Length

.

Sets the length of the serial data word. The length of the

data word can be set to 7 or 8 bits and must match the corresponding
data bits setting in the PNE. The factory default is 8.

Stop Bits.

Sets the number of stop bits in the serial data word. Either 1 or

2 stop bits can be selected. The setting must match the corresponding
stop bit setting in the PNE. The factory default is 1.

Parity

. The options are Odd, Even, Mark, Sense, or None. The setting

must match the corresponding parity setting in the PNE.

The factory default is None.

Modem

This menu enables or disables the modem interface. After changing the
modem menus, save the configuration as the power-up configuration and
reboot the printer. The factory default is Disable.

NOTE:

Connect the modem to the selected serial interface for printer
management (debug or host serial), and power on the modem before
powering on the printer. The printer will search for a modem at

power-up, and display a message on the printer front panel if a
modem is detected.

Modem NVM

This setting defines whether the modem configuration, as stored in the
modem's NVM, should be used, or if the printer should send a modem
initialization string. When enabled, the printer will only send an ATZ0
command to the modem on power-up. This command resets the modem
to configuration 0. When disabled, the printer sends a generic modem
initialization string on power-up. The factory default is Enable.

NOTE:

This generic initialization string does not work for all modem types.

If the initialization string does not work, the modem must be
configured manually, the setting must be stored in configuration 0,
and the printer 'Modem NVM' menu must be set to enable.

Modem Status

Enable

(factory default). Displays the modem status commands on

the printer control panel.

Disable

. Does not display the modem status commands on the

printer control panel.

Dial Method

Tone

(factory default). Sets the modem to use the tone dialing

method.

Pulse

. Sets the modem to use the pulse dialing method.

PNE Port Number

. This menu selects the port number the printer

expects the PNE to connect through. The factory default is 3001 and the
range is from 1023 to 65535.