The following example shows how to restrict the traffic received on port 1 to
tagged frames:

Related Commands
switchport mode (4-202)

switchport ingress-filtering
This command enables ingress filtering for an interface. Use the no form to
restore the default.
Syntax

[no] switchport ingress-filtering

Default Setting

Disabled

Command Mode

Interface Configuration (Ethernet, Port Channel)

Command Usage
• Ingress filtering only affects tagged frames.
• If ingress filtering is disabled and a port receives frames tagged for VLANs for
which it is not a member, these frames will be flooded to all other ports (except for
those VLANs explicitly forbidden on this port).
• If ingress filtering is enabled and a port receives frames tagged for VLANs for
which it is not a member, these frames will be discarded.
• Ingress filtering does not affect VLAN independent BPDU frames, such as
GVRP or STA. However, they do affect VLAN dependent BPDU frames, such as
GMRP.
Example
The following example shows how to set the interface to port 1 and then enable
ingress filtering: