S

WITCH

#5:

F

RAME

R

ATE

:

S

WITCH

#6:

F

RAME

R

ATE

:

These two switches are used to select the frame rate being used by the MiniBrain. They are

used as follows:

Switch #4

Switch #5

Switch #6

Frame rate

OFF or ON

OFF

OFF

15 FPS

OFF or ON

ON

OFF

16 FPS

OFF or ON

OFF

ON

30 FPS

OFF

ON

ON

External Clock through Blue Input

ON

ON

ON

32 FPS

The 32 FPS frame rate is unavailable unless the card is using the Blue input for selecting a sec-

ond show. When external clock is selected, the frames displayed on a heads up display will carry
into the seconds every thirty frames, no matter what rate the frames are actually arriving at the
MiniBrain.

S

WITCH

#7:

S

TOP

O

N

G

REEN

O

PENING

:

When this switch is turned on, the MiniBrain will stop when the Green input is opened. This

switch is used when you would like the show to run AS LONG as the Green input is closed. The
MiniBrain will start playing when the Green input is activated, and stop when the Green input is
deactivated.

S

WITCH

#8:

R

UN

C

ONTINUOUS

:

This switch works in parallel with the Green input. When it is ON, the MiniBrain will start playing.

At the end of a show, the MiniBrain will reset back to the first frame and continue playing from the
beginning of the show. This switch can be used to start a show playing, or if it is left ON the
MiniBrain will start playing as soon as power is applied and will loop at the end of the show. Note
that when this switch is left ON, the Green input is disabled.