column) of the 40 pin IDS connector. The first and last ten pins are bussed to all of the cards in the card
cage.
The 1/4 J6 Input is optically isolated. It can be set to run from an external power source (default con-
figuration) or the same power as the Rack Smart Brick Brain. This is selected by moving the two jumpers
on JP-2 as shown on the board. Both jumpers to the left set the 1/4 J6 to internal power. Both jumpers to
the right set the 1/4 J6 to external power.
SUPPLY (not used)
+
(Brown) PIN #1
(red) PIN #2
(orange) PIN #3
(yellow) PIN #4
(green) PIN #5
(blue) PIN #6
(violet) PIN #7
(grey) PIN #8
(white) PIN #9
(black) PIN #10
GROUND (not used)
DATA BIT 7
DATA BIT 6
DATA BIT 5
DATA BIT 4
DATA BIT 3
DATA BIT 2
DATA BIT 1
DATA BIT 0
+ 5 to 24 VDC SUPPLY
GROUND
DATA BIT 7
DATA BIT 6
DATA BIT 5
DATA BIT 4
DATA BIT 3
DATA BIT 2
DATA BIT 1
DATA BIT 0
Internal Power
External Power
(Brown) PIN #1
(red) PIN #2
(orange) PIN #3
(yellow) PIN #4
(green) PIN #5
(blue) PIN #6
(violet) PIN #7
(grey) PIN #8
(white) PIN #9
(black) PIN #10
The Connections to the J-8 input are as follows. These inputs are optoisolated. You must provide a
voltage to them:
+
+ GREEN #18
- BLUE #19
+ BLUE #20
+ 5 to 24 VDC SUPPLY
+
- GREEN #17
+ 5 to 24 VDC SUPPLY
+ GREEN #18
- BLUE #19
+ BLUE #20
+
+ 5 to 24 VDC SUPPLY
+
- GREEN #17
+ 5 to 24 VDC SUPPLY
Switching Positive Side
Switching Negative Side
The J8 input has the same functionality as the J-8 connections found on all of our normal Micro
MACs Bricks. Facing the end of the RJ-11 plug with the latch upward, the order of these inputs is as fol-
lows:
COLOR
SIGNAL NAME:
1)
WHITE: not
used
2)
BLACK:
common + 5 to 24 VDC (15 Volts nominal) input
3)
RED: not
used
4)
GREEN:
optically isolated input
5)
YELLOW: not
used
6)
BLUE:
optically isolated input
G