In addition to these connections, the IR Receiver requires a 7 to 24 volt DC power supply connec-
tion. This is normally attached to the two pads marked Т+У and Т-У on the receiver. A jumper option allows
you to bring this in through the blue wire on the RJ-11 connector.
The IR Transmitter has an eight position dipswitch which sets which show it selects. The lower nibble
of the address are set with the first four switches, and the upper nibble is set with the last four. Valid show
numbers are 01h through FFh:
S
WITCH
#1
S
WITCH
#2
S
WITCH
#3
S
WITCH
#4
L
OWER
NIBBLE
OF
A
DDRESS
OFF
OFF
OFF
OFF
x0h
ON
OFF
OFF
OFF
x1h
OFF
ON
OFF
OFF
x2h
ON
ON
OFF
OFF
x3h
OFF
OFF
ON
OFF
x4h
ON
OFF
ON
OFF
x5h
OFF
ON
ON
OFF
x6h
ON
ON
ON
OFF
x7h
OFF
OFF
OFF
ON
x8h
ON
OFF
OFF
ON
x9h
OFF
ON
OFF
ON
xAh
ON
ON
OFF
ON
xBh
OFF
OFF
ON
ON
xCh
ON
OFF
ON
ON
xDh
OFF
ON
ON
ON
xEh
ON
ON
ON
ON
xFh
S
WITCH
#5
S
WITCH
#6
S
WITCH
#7
S
WITCH
#8
U
PPER
NIBBLE
OF
A
DDRESS
OFF
OFF
OFF
OFF
0xh
ON
OFF
OFF
OFF
1xh
OFF
ON
OFF
OFF
2xh
ON
ON
OFF
OFF
3xh
OFF
OFF
ON
OFF
4xh
ON
OFF
ON
OFF
5xh
OFF
ON
ON
OFF
6xh
ON
ON
ON
OFF
7xh
OFF
OFF
OFF
ON
8xh
ON
OFF
OFF
ON
9xh
OFF
ON
OFF
ON
Axh
ON
ON
OFF
ON
Bxh
OFF
OFF
ON
ON
Cxh
ON
OFF
ON
ON
Dxh
OFF
ON
ON
ON
Exh
ON
ON
ON
ON
Fxh
When in this mode you must also set the baud rate to 1200 baud and the ÔEARLY STARTSÕ should be
set to ÔIGNOREÕ. Any binary show number received by the serial port for more times than the value stored
in the DEBOUNCE variable will trigger that show. Typically the transmitters are placed along the path of
the vehicleÕs travel to trigger the appropriate animation sequences at the appropriate times.
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
ÒjÓ
Coin-Op Mode:
This toggle turns on a special mode that is typically used with animation systems that are installed in
coin operated devices. When this toggle is switched ON:
1)
If no other show is playing and we arenÕt in a delay countdown, the Rack Smart Brick Brain will
start playing show 255/FFh. This can be stopped if there is a closure on the BLUE input.
2)
The end of the delay countdown will always call up show 255/FFh.
Show 255/FFh is then programmed as the ÔattractÕ mode for the installation. Other shows are typical-
G
ILDERFLUKE
& C
O
.¥ 205 S. F
LOWER
S
T
.¥ B
URBANK
, CA 91502 ¥ 818/840-9484 ¥ 800/776-5972 ¥
FAX
818/840-9485