By adding a pushbutton switch to the connections shown above, you can make an easier to use

programming console that has a separate Ôprogramming enableÕ switch and pushbutton for turning on
and off the output

+15V

from brick output

momentary
programing
s w i t c h

to brick input

to show

rec.

play

SPDT
s w i t c h

For building an analog programming console, we recommend you use our Analog to Digital (A/D)

Converters. One is used for each analog function on your console. In this case the wires Ôfrom brick out-
putÕ, Ôto brick inputÕ, and Ôto showÕ are actually eight wires (plus ground and + supply) that make up a 1/4
J-6 cable:

potentiometer

r ecor d anal og

pl ayback

f r om br i ck out put

t o br i ck i nput

t o show

SPST
sw i t ch

A/ D

G

ILDERFLUKE

& C

O

.¥ 205 S. F

LOWER

S

T

.¥ B

URBANK

, CA 91502 ¥ 818/840-9484 ¥ 800/776-5972 ¥

FAX

818/840-9485

25 of 134