IAI America XSEL-KX User Manual

Page 182

Advertising
background image




166

Part 4 Commands


 PATH (Move along path in CP operation)

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command, declaration

Output

(Output, flag)

Command,
declaration

Operand 1

Operand 2

Optional

Optional

PATH

Start

position

number

End

position

number

PE

[Function] Move continuously from the position specified in operand 1 to the position specified in

operand 2.
The output type in the output field can be set using an actuator-declaration command POTP.
Increasing the acceleration will make the passing points closer to the specified positions.
If invalid data is set for any position number between the start and end position numbers, that
position number will be skipped during continuous movement.













(Note 1)

Multi-dimensional movement can be performed using a PATH command.
In this case, input in operand 1 the point number of the next target, instead of the predicted
current position upon execution of the applicable command.
(Inputting a point number corresponding to the predicted current position will trigger
movement to the same point during continuous movement, thereby causing the speed to
drop.)


[Example 1]

PATH

100

120

Move continuously from position Nos. 100 to 120.

Start position

Position origin

End position

Advertising
This manual is related to the following products: