316

Appendix

7. Other Parameters

No.

Parameter name

Default value

(Reference)

Input range

Unit

Remarks

1

Auto-start program
number

0

0 ~ 64

(Invalid if “0” is set)

2

I/O processing
program number at
operation/program
abort

0

0 ~ 64

The start trigger is determined from the “I/O
processing program start type at
operation/program abort.” (Note: This program
will be started before confirming an abort of other
programs.)
(Invalid if “0” is set) * If the setting is valid, the
number of user program tasks that can be used
will decrease by 1.

3

I/O processing
program number at all
operation pause

0

0 ~ 64

This program will be started when an all-
operation-pause command is issued due to an all-
operation-pause factor. (Only when a program is
running) (Invalid if “0” is set) * If the setting is
valid, the number of user program tasks that can
be used will decrease by 1.

4

Program abort type at
error

0

0 ~ 5

0: Cancel only the program in which an error of

operation-cancellation level or higher has
generated. (If the error requires the drive
source to be cut off, servo OFF or all-axis
servo OFF, all programs other than the “I/O
processing program at operation/program
abort” will be cancelled.)

1: Cancel all programs other than the “I/O

processing program at operation/program
abort” when an error of operation-cancellation
level or higher has generated.

5

I/O processing
program start type at
operation/program
abort

0

0 ~ 5

0: When all-operation-cancellation factor has

generated (Only when a program is running)

1: When all-operation-cancellation factor has

generated (Always)

2: All-operation-cancellation factor + Error of

operation-cancellation level or higher (“Other
parameter No. 4 = 0” is considered) (Only
when a program is running)

3: All-operation-cancellation factor + Error of

operation-cancellation level or higher (“Other
parameter No. 4 = 0” is considered) (Always)

6

PC/TP reconnection
delay at software reset

11000

1 ~ 99999

msec

* The new setting will become effective after the

controller, PC software or TP is restarted.
(Main application version 0.25 or later)

7~8 (For extension)

0

9

Deadman-switch
recovery type

0

0 ~ 2

0: Abort operations/programs
2: Operation continued (Only during automatic

operation. * In the PC software version is
1.0.0.5 or later or TP application version is
1.01 or later, operation commands from the
PC software/TP will be aborted on the PC
software/TP side.)