Release of emergency stop – IAI America XSEL-KX User Manual

Page 298

Advertising
background image




282

Part 4 Commands

2. Release of Emergency Stop

Default factory settings of parameters

“Other parameter No. 10, Emergency-stop recovery type” = 0
“Other parameter No. 11, Safety-gate open recovery type” = 0
“Other parameter No. 12, Recognition type during automatic operation” = 0

An emergency stop is actuated by turning the emergency-stop contact b input to OFF, and released
by turning the input to ON.


(1) Flow chart

(2) Timing chart

























The selected program is executed from step 1.



 The internal conditions of the controller during an emergency stop are as follows:

• Programs

Aborted (excluding “I/O processing programs

operation when program is aborted”)

• Output ports, local flags, local

variables

Cleared

• Global flags, global variables

Retained

If the peripherals are to be controlled by program, create a management program beforehand and use
the program to control the peripherals. Alternatively, start (EXPG) or abort (ABPG) other programs in
accordance with the status of each general-purpose input.

Emergency stop is

actuated

Emergency

stop

Alarm

reset?

Ready

output ON?

Program number output

External start (000) input

NO

NO

NO

YES

YES

YES

Emergency-stop input

(contact b)



Ready output



Emergency-stop output



Teaching-pendant restart

input


Program number output



General-purpose output

Emergency-stop release timing on X-SEL Controller

0


0



0




0

0


0

Advertising